SIGMA THERMAL HC2-1.5-D-SF 0.6 MMBTU/Hr. Oil-Fired Vertical Downfired Thermal Fluid Heating System, Originally Installed for a Vacuum Kiln, but Never Used in Production!
Specifications:
Heat input 0.6 MMBTU/Hr.
Flow rate 85 Gallons/Min.
Operating temperature: 400° F Supply & 369° Return.
Operating pressure 53 PSIG.
Design flow mass rate 31,898 Lbs./Hr.,
Design flow volume rate 85 GPM.
Heat transfer fluid type: Paratherm HE.
Fuel type: No. 2 Oil.
Equipped with:
MAXON "OVENPAK EBC2" Oil-fired burner, with Firing Rate (HHV Basis): 703,519 BTU/Hr. Steady State & 773,871 BTU/Hr. Design State, and 6 Gallons/Hr. Fuel flow rate.
Heater coil, with 750° F Operating temperature.
15 HP Heat transfer fluid pump.
40" Dia. x 80" H Vertical oiler tank, with 250 PSI at 750° F Max. Allowable working pressure.
120 Gallon Cap. Horizontal expansion tank, with 140 PSI at 600° F Max. Allowable working pressure.
Control, with FIREYE "BurnerLogix BLL110" Digital burner management controller, YOKOGAWA ELECTRIC "PV" Digital temperature controller, & (3) YOKOGAWA ELECTRIC "UT150L" Digital temperature limit controllers.
(3) PROCESS CONTROL SPECIALTIES VacuDry Kilns Vacuum Kiln Controls, Each with UNITRONICS "Vision530" PLC with 5.7" Graphic LCD touchscreen & AUTOMATION DIRECT "DURApulse GS3-4100" 100 HP AC Drive with LCD Touchpad controller.
(2) BENSHAW "RSI-125-SG-4B" 125 HP Variable Speed Drives, Each with LCD Touchpad controller.
Component Dimensions:
Boiler Tank with Control & Framework: 84" x 68" x 128" H.
Expansion Tank with Pump & Framework: 96" x 70" x 130" H.
Burner Piping with Pallet: 64" x 46" x 15" H.
Heat Exchanger: 118" x 70" x 19" H.
Pipe: 22" x 18" x 254" H.
(3) Kiln Controls: 96" x 22" x 109" H, 102" x 22" x 72" H, & 96" x 22" x 72" H.
Variable Speed Drive with (3) Switch Boxes & Pallet: 36" x 15" x 80" H.
Variable Speed Drive with Pallet: 16-1/2" x 20" x 31-1/2" H.
SIGMA THERMAL HC2-1.5-D-SF 0.6 MMBTU/Hr. Oil-Fired Vertical Downfired Thermal Fluid Heating System, Originally Installed for a Vacuum Kiln, but Never Used in Production!
Specifications:
Heat input 0.6 MMBTU/Hr.
Flow rate 85 Gallons/Min.
Operating temperature: 400° F Supply & 369° Return.
Operating pressure 53 PSIG.
Design flow mass rate 31,898 Lbs./Hr.,
Design flow volume rate 85 GPM.
Heat transfer fluid type: Paratherm HE.
Fuel type: No. 2 Oil.
Equipped with:
MAXON "OVENPAK EBC2" Oil-fired burner, with Firing Rate (HHV Basis): 703,519 BTU/Hr. Steady State & 773,871 BTU/Hr. Design State, and 6 Gallons/Hr. Fuel flow rate.
Heater coil, with 750° F Operating temperature.
15 HP Heat transfer fluid pump.
40" Dia. x 80" H Vertical oiler tank, with 250 PSI at 750° F Max. Allowable working pressure.
120 Gallon Cap. Horizontal expansion tank, with 140 PSI at 600° F Max. Allowable working pressure.
Control, with FIREYE "BurnerLogix BLL110" Digital burner management controller, YOKOGAWA ELECTRIC "PV" Digital temperature controller, & (3) YOKOGAWA ELECTRIC "UT150L" Digital temperature limit controllers.
(3) PROCESS CONTROL SPECIALTIES VacuDry Kilns Vacuum Kiln Controls, Each with UNITRONICS "Vision530" PLC with 5.7" Graphic LCD touchscreen & AUTOMATION DIRECT "DURApulse GS3-4100" 100 HP AC Drive with LCD Touchpad controller.
(2) BENSHAW "RSI-125-SG-4B" 125 HP Variable Speed Drives, Each with LCD Touchpad controller.
Component Dimensions:
Boiler Tank with Control & Framework: 84" x 68" x 128" H.
Expansion Tank with Pump & Framework: 96" x 70" x 130" H.
Burner Piping with Pallet: 64" x 46" x 15" H.
Heat Exchanger: 118" x 70" x 19" H.
Pipe: 22" x 18" x 254" H.
(3) Kiln Controls: 96" x 22" x 109" H, 102" x 22" x 72" H, & 96" x 22" x 72" H.
Variable Speed Drive with (3) Switch Boxes & Pallet: 36" x 15" x 80" H.
Variable Speed Drive with Pallet: 16-1/2" x 20" x 31-1/2" H.